Abstract

The purpose of this project was to determine the accuracy, precision, linearity and Method Detection Limit (MDL) for tributyltin (TBT) analytical techniques available at the Virginia Institute of Marine Science prior to implementing an environmental monitoring program in the Elizabeth River, Virginia. This precursory work is to document the ability of analytical techniques to accurately detect TBT in ambient water samples at concentrations of 1 ng/L and greater.

Description

A Report to The Virginia Department of Environmental Quality

DOI

doi: 10.25773/g0z4-ma46