Document Type
Article
Department/Program
Physics
Journal Title
Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment
Pub Date
2016
Volume
808
First Page
1
Abstract
Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. Before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. The calculated beam position will be used in the data analysis to accurately determine the kinematics for each event. (C) 2015 Elsevier B.V. All rights reserved.
Recommended Citation
Zhu, Pengjia; Ye, Yunxiu; Allada, Kalyan; and Cummings, Melissa, Beam position reconstruction for the g2p experiment in Hall A at Jefferson lab (2016). Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 808, 1-10.
10.1016/j.nima.2015.10.086
DOI
10.1016/j.nima.2015.10.086